A 2024 cluster of Mycobacterium abscessus infections at a Maryland hospital was linked to contamination of the hospital water system, with ice machines implicated as a probable source, according to an investigation published in Emerging Infectious Diseases.
Lead author Sarah Ludmer, an epidemiologist and consultant at the Maryland Department of Health who is also affiliated with CDC, and colleagues investigated the cluster after hospital infection prevention staff identified an initial case in May 2024.
M. abscessus is a nontuberculous mycobacterium found naturally in soil, dust and water. It can cause skin and soft tissue infections, bloodstream infections and pulmonary disease and can be difficult to treat because of intrinsic drug resistance. Outbreaks in health care settings have previously been associated with contaminated water sources.
Investigation points to hospital water system
A retrospective review initially identified 10 patients with M. abscessus-positive cultures collected between March 2023 and June 2024. An additional patient was identified in September 2024, bringing the total to 11. The patients had a median age of 40 years, and six received antimicrobial treatment after their positive cultures.
After reviewing the clinical and epidemiologic data, investigators classified six patients as having clinical infections and five as likely representing colonization or specimen contamination. One patient died within 60 days of the first positive culture, but the death was not attributed to M. abscessus.
Before mitigation measures began, investigators collected 47 environmental samples from 19 locations throughout the hospital, including bulk water and swabs from faucets, sinks and ice machines. Eighteen samples, or 38%, grew M. abscessus. The organism was detected at different levels throughout the hospital building, including in ice machines.
Whole-genome sequencing showed that patient and environmental isolates clustered into five genetic subclusters. Four included both patient and environmental isolates, supporting a link between the hospital water system and the infections.
One patient isolate was an exact genetic match to a sample from an ice machine in the postanesthesia care unit. Two other patient isolates were closely related to environmental samples from the same area. Combined with the epidemiologic findings, the sequencing results confirmed colonization of the hospital water system and implicated ice machines as a probable source of infection.
Mitigation efforts show varying effectiveness
After the first two cases were identified in 2024, the hospital implemented several measures, including hospital-wide water flushing, increased supplemental disinfectant levels, restrictions on tap water and ice machine use and staff education on sink safety. Point-of-use filters were also installed in high-risk areas, including intensive care units, operating room scrub sinks and cancer centers.
Point-of-use filters appeared to be the most effective intervention. Follow-up samples from locations where the filters were installed showed no bacterial growth, although the authors noted that the filters are expensive and require regular inspection and replacement. In contrast, M. abscessus continued to be detected after hospital-wide flushing and increased disinfectant levels, suggesting those measures produced only a temporary reduction. The hospital ultimately updated its water management plan to include more frequent building flushing, residual disinfectant testing and specific testing for M. abscessus.
The findings underscore the difficulty of eliminating M. abscessusonce biofilm has developed in a water system. The investigators said swift action to remove potential sources of exposure from patient areas was likely important in preventing additional infections. They also emphasized robust water management plans and sink-safety education as important measures for preventing outbreaks involving M. abscessusand other water-associated pathogens.
No conflicts of interest were reported in the published article.