Overview

An investigation at a Maryland hospital identified 10 patients with Mycobacterium abscessus-positive cultures collected between March 2023 and June 2024, followed by an additional patient identified in September 2024. Genomic and epidemiologic findings linked the cluster to the hospital water system, with ice machines implicated as a probable source. Follow-up samples from locations with point-of-use filters showed no bacterial growth.

Background

M. abscessus is a nontuberculous mycobacterium found naturally in soil, dust and water. It can cause skin and soft tissue infections, bloodstream infections and pulmonary disease and can be difficult to treat because of intrinsic drug resistance.

Health care–associated outbreaks have previously been linked to contaminated water sources. After hospital infection prevention staff identified an initial case in May 2024, investigators reviewed clinical and epidemiologic data, collected environmental samples and compared patient and environmental isolates using whole-genome sequencing.

Data Highlights

Measure

Finding

Patients identified

10 with positive cultures collected between March 2023 and June 2024; an additional patient identified in September 2024 brought the total to 11

Clinical classification

6 clinical infections; 5 likely colonization or specimen contamination

Antimicrobial treatment

6 patients received treatment after positive cultures

Environmental sampling before mitigation

47 samples from 19 hospital locations

Environmental samples positive for M. abscessus

18 of 47 (38%)

Genomic clusters

5 subclusters; 4 included both patient and environmental isolates

Mortality

1 patient died within 60 days of the first positive culture; the death was not attributed to M. abscessus

Key Findings

  • Investigators classified six patients as having clinical infections and five as likely representing colonization or specimen contamination. The patients had a median age of 40 years.

  • Before mitigation, environmental sampling included bulk water and swabs from faucets, sinks and ice machines. M. abscessus was detected throughout the hospital, including in ice machines.

  • Four of five genetic subclusters contained both patient and environmental isolates, supporting a link to the hospital water system.

  • One patient isolate exactly matched a sample from a postanesthesia care unit ice machine. Two other patient isolates were closely related to environmental samples from the same area.

  • Combined genomic and epidemiologic findings confirmed colonization of the hospital water system and implicated ice machines as a probable infection source.

  • Follow-up samples from locations with point-of-use filters showed no bacterial growth. The organism remained detectable after hospital-wide flushing and increased disinfectant levels, suggesting those measures produced only temporary reductions.

Clinical Implications

The hospital implemented water flushing, increased supplemental disinfectant levels, restrictions on tap water and ice machine use, staff sink-safety education and point-of-use filters in high-risk areas.

Filters appeared to be the most effective intervention, although they are expensive and require regular inspection and replacement. Investigators emphasized that established biofilm makes M. abscessus difficult to eliminate from water systems.

The hospital updated its water management plan to include more frequent building flushing, residual disinfectant testing and specific M. abscessus testing. Investigators considered swift removal of potential exposure sources from patient areas likely important in preventing additional infections.

Conclusion

The investigation linked the cluster to the hospital water system and implicated ice machines as a probable source. Persistent detection after flushing and increased disinfectant levels highlighted mitigation challenges. Investigators emphasized robust water management, sink-safety education and prompt action to reduce patient exposure.