Health Care-Associated Infections Sepsis & Critical Care Antimicrobial Resistance & Stewardship Clinical Care & Diagnostics

Hospital water system linked to Mycobacterium abscessus cluster

Share

Clinical Scorecard: Hospital water system linked to Mycobacterium abscessus cluster

At a Glance

Category

Detail

Condition

A hospital-associated Mycobacterium abscessus cluster involving clinical infections and likely colonization or specimen contamination

Key Mechanisms

M. abscessus occurs naturally in soil, dust and water and can cause skin and soft tissue infections, bloodstream infections and pulmonary disease. Genetic and epidemiologic findings linked the cluster to the hospital water system and implicated ice machines as a probable source.

Target Population

Patients with M. abscessus-positive cultures in the investigated Maryland hospital cluster

Care Setting

Hospital water systems and patient-care areas, including ice machines and locations receiving point-of-use filters

Key Highlights

  • Investigators initially identified 10 patients with positive cultures collected between March 2023 and June 2024. An additional patient was identified in September 2024, bringing the total to 11.

  • Six patients were classified as having clinical infections; five likely represented colonization or specimen contamination.

  • M. abscessus grew from 18 of 47 environmental samples (38%) collected from 19 hospital locations.

  • Whole-genome sequencing identified five genetic subclusters; four contained both patient and environmental isolates.

  • One patient isolate exactly matched a sample from a postanesthesia care unit ice machine. Two other patient isolates were closely related to environmental samples from the same area.

  • Follow-up samples from locations with point-of-use filters showed no bacterial growth. M. abscessus remained detectable after hospital-wide flushing and increased disinfectant levels.

Guideline-Based Recommendations

The source describes investigation methods and outbreak-control measures rather than a formal clinical guideline.

Diagnosis

  • Investigators reviewed clinical and epidemiologic data to distinguish clinical infections from likely colonization or specimen contamination.

  • Environmental sampling included bulk water and swabs from faucets, sinks and ice machines.

  • Whole-genome sequencing compared patient and environmental isolates, supporting a link to the hospital water system.

Management

  • The hospital implemented water flushing, increased supplemental disinfectant levels, restrictions on tap water and ice machine use, and staff sink-safety education.

  • Point-of-use filters were installed in high-risk areas, including intensive care units, operating room scrub sinks and cancer centers.

  • The water management plan was updated to include more frequent building flushing, residual disinfectant testing and specific M. abscessus testing.

Monitoring & Follow-up

  • Follow-up environmental sampling assessed mitigation measures.

  • Samples from locations with point-of-use filters showed no bacterial growth.

  • Continued detection after flushing and increased disinfectant levels suggested those measures produced only temporary reductions.

  • Point-of-use filters require regular inspection and replacement.

Risks

  • M. abscessus can cause skin and soft tissue infections, bloodstream infections and pulmonary disease and can be difficult to treat because of intrinsic drug resistance.

  • Established biofilm makes the organism difficult to eliminate from water systems.

  • One patient died within 60 days of the first positive culture, but the death was not attributed to M. abscessus.

Patient & Prescribing Data

The 11 patients had a median age of 40 years. Six received antimicrobial treatment after their positive cultures.

The source does not identify antimicrobial regimens or provide comparative treatment outcomes. The six patients classified as having clinical infections and the six who received treatment are reported separately; the supplied article does not explicitly establish that they were the same patients.

Clinical Best Practices

  • Maintain robust water management plans and provide sink-safety education.

  • Remove potential sources of exposure from patient areas promptly; investigators considered swift action likely important in preventing additional infections.

  • Consider the reported effectiveness of point-of-use filters alongside their expense and need for regular inspection and replacement.

  • Use environmental sampling, genomic analysis and epidemiologic findings together when investigating potential water-associated clusters.

Related Resources & Content

  • Hospital water system linked to Mycobacterium abscessus cluster — Meg Barbor — IDSA Reporter — October 6, 2026 — https://idsareporter.com/issues/2026/october-2026/hospital-water-system-linked-to-mycobacterium-abscessus-cluster/.

  • Investigation of Mycobacterium abscessus Cluster in Hospital, Maryland, USA, 2024 — Ludmer S, Duwell M, Harris T, et al — Emerging Infectious Diseases — Published online August 5, 2026; September 2026;32(9):1397-1401 — https://doi.org/10.3201/eid3209.260093.